CDN2000A-06-32 - three phase CDN with automatic coupling path selection

(Published in September 2002)

The CDN2000A-06-32 is a coupling de-coupling network for surge, ring and EFT testing. The CDN can be used with all TRA2000 and the MIG0603INx generators. Two different versions are available: one for a power supply of 240/415 V and one for 280/480 V.


Rating: Supply Voltage (a.c. or d.c.):
L to N/PE 240 V, L to L 480 V

Supply Current:
Continuous operation (a.c. or d.c.): 3 x 32 A
Continuous operation (d.c.): 1 x 64 A

Test Voltages:
Surge voltage: maximum 6.6 kV
Ring voltage: maximum 6.6 kV
EFT voltage: maximum 6.3 kV


enlarge


enlarge


enlarge

Control:
RS232 connection from the rear side of the TRA2000 or MIG0603INx to the CDN2000A-06-32

For the selection of the coupling paths see the displays on the right.

Power supply: 90 to 240 V and 50/60Hz

Standards: IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4

Option: 480V: for power supply L to N/PE 280 V and L to L 480 V

For use with these generators: TRA2000, TRA2000IN4,
TRA2000IN6, MIG0603IN,
MIG0603IN1, MIG0603IN3,
MIG0603IN4



For more information please have a look at