Below you find short descriptions of EMC PARTNER's products for
as well as for
The ring wave test is also included in the One Box EMC Test Station.
| Waveform (Range): | 1 MHz (up to 3 kV), 100 kHz (up to 3 kV), |
![]() enlarge |
| Impedance: | 200 Ohm | |
| Standards: | IEC 60255-5, IEC 61000-4-18 | |
| Option: | MF IEC 61000-4-10 | |
| Required Accessory: |
CDN2000-06-25 |
For more information please have a look at
This addition to the damped oscillatory test system adds the 3MHz, 10MHz and 30MHz fast waves to existing generators of type MIG-OS-OS1, MIG0603OS1, MIG-OS-OM and MIG0603OMI
| Waveforms (Range): |
Damped sine wave: 3MHz, 10MHz and 30MHz open circuit (up to 4 kV) |
![]() enlarge |
| Standards: | IEC61000-4-18 | |
| Accessories: |
CDN3000A-06-25 Power line coupling and de-coupling filter: CWG, 100kHz Ringwave, EFT and Damped oscillatory wave (100kHz, 1MHz, 3MHz, 10MHz, 30MHz) coupling onto 3-Phase power lines up to 6 kV |
![]() enlarge |
For more information please contact the representative in your region.
| Waveforms (Range): | 1 MHz, 100 kHz (up to 3kV, 1 MHz, 100 kHz (up to 100 A/m) CWG 1.2/50 µs, 8/20 µs (6 kV, 3 kA) 0.5 J, 500 Ohm (0.5, 1, 3, 5 kV) 8/20 µs (up to 2000 A/m) a.c. 50/60 Hz (continuous up to |
![]() enlarge |
| Coupling: | fields: MF1000-1, MF1000-2, a.c.: CDN2000-06-25 up to 4 I/o lines: CND2000-06-25 |
|
| Standards: | IEC 61000-4-5, IEC 61000-4-8, |
|
| Required Accessories: | CDN2000-06-25, MF1000-1, |
For more information please have a look at
The MIG-OS-OM includes damped oscillatory tests 1 MHz and 100 kHz up to 3 kV in accordance with EN/IEC 61000-4-18. This standard defines a dual output for differential mode tests. Additionally magnetic field test in accordance with EN/IEC 61000-4-10 can be carried out.
| Waveforms (Range): |
Damped sine wave: 100 kHz and 1 MHz open circuit (up to 3kV) source impedance 200 Ohm |
![]() enlarge |
| Standards: | IEC61000-4-10, IEC61000-4-18, ANSI C37-90 | |
| Accessories: | CDN2000A-06-25 power line coupling and de-coupling filter: CWG, 100kHz Ringwave, EFT and damped oscillatory wave (100kHz, 1MHz) coupling onto 3-phase power lines up to 6 kV |
![]() enlarge |
| MF1000-1 magnetic field antenna: Accessory to the MIG-OS-OM. Enables magnetic field testing up to 120A/m at both 100 kHz and 1 MHz. |
![]() enlarge |
For more information please contact the representative in your region.
The MIG0603OSI includes damped oscillatory tests 1 MHz and 100 kHz up to 3 kV in accordance with EN/IEC 61000-4-18. Additional waveforms extend the application to include EN/IEC61000-4-5 and EN/IEC60255-22-1.
| Waveforms (Range): |
Damped sine wave: 100 kHz and 1 MHz open circuit (up to 3kV) source impedance 200 Ohm CWG 1.2/50 µs, 8/20 µs (6 kV, 3 kA) source impedance 2 Ohm 1.2/50 µs (up to 6 kV) source impedance 500 Ohm |
![]() enlarge |
| Standards: | EN/IEC61000-4-18, ANSI C37-90, EN/IEC61000-4-5, EN/IEC61000-4-9, EN/IEC60255-22, EN/IEC60255-5 | |
| Accessories: | CDN2000A-06-25 power line coupling and de-coupling filter: CWG, 100kHz Ringwave, EFT and damped oscillatory wave (100kHz, 1MHz) coupling onto 3-phase power lines up to 6 kV |
![]() enlarge |
For more information please contact the representative in your region.
| Waveform (Range): | Ring 100 kHz (up to |
![]() enlarge |
| Coupling: | a.c.: single phase 16 A d.c.: 16 A / 110 V |
|
| Standards: | IEC 61000-4-12, |
For more information please contact the representative in your region.