Immunity: Surge

Below you find short descriptions of EMC PARTNER's products for surge tests

TRA2000 Version SURGE - Surge up to 4 kV

Waveforms (Range): v = 1.2/50 µs (0.25 kV up to 4.1 kV), i = 8/20 µs (0.125 kA up to 2.1 kA)
enlarge
Coupling: single phase 16 A
Standard: IEC 61000-4-5
Required Accessory:
 
CDN-KIT1000


For more information please have a look at

MIG0603IN - Surge up to 6 kV

Waveforms (Range): 1.2/50 µs (0.25 to 6.2 kV), 8/20 µs (0.125 kA up to 3.1 kA )
enlarge
Coupling: single phase 16 A
Standards: IEC 61000-4-5, ITU K.17
Options: Ring wave 0.5 µs/100 kHz, 10/700 µs
Required Accessory: CDNKIT1000


For more information please have a look at

CDN2000-06-32 and CDN2000A-06-32

Rating: Supply Voltage (a.c. or d.c.):
L to N/PE 240 V, L to L 480 V

Supply Current:
Continuous operation (a.c. or d.c.): 3 x 32 A
Continuous operation (d.c.): 1 x 64 A

Test Voltages:
Surge voltage: maximum 6.6 kV
Ring voltage: maximum 6.6 kV
EFT voltage: maximum 6.3 kV


enlarge


enlarge


enlarge

Control:
RS232 connection from the rear side of the TRA2000 or MIG0603INx to the CDN2000A-06-32

For the selection of the coupling paths see the displays on the right.

Power supply: 90 to 240 V and 50/60Hz

Standards: IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4

Option: 480V: for power supply L to N/PE 280 V and L to L 480 V

For use with these generators: TRA2000, TRA2000IN4,
TRA2000IN6, MIG0603IN,
MIG0603IN1, MIG0603IN3,
MIG0603IN4



For more information please have a look at

MIG0603-3P100 - Surge up to 6 kV onto 100 A a.c.

Waveforms (Range): 1.2/50 µs (0.25 up to 6.2 kV)
8/20 µs (0.125 kA up to 3.1 kA)

enlarge
Coupling: three phase 100 A
Standards: IEC 61000-4-5
Required Accessory: CDNKIT1000
Option:
























EFT


For more information please have a look at

MIG1206 - Surge up to 12 kV

Waveforms:
(Range)
CWG 1.2/50, 8/20 µs (12 kV, 6 kA)
enlarge
Standards: IEC 61000-4-5, ITU-T K.44, K.20, K.21
Coupling using CDN-MIG12-32: Power supply a.c. L-L/N 480V, 32 A
Power supply a.c. L/N to PE 280 V
Power supply d.c. 280 V, 32 A
Accessories: see accessories for telecom coupling
Further Accessories: TEMA (Test Manager Software)


For more information please have a look at

MIG1206-xP-32

The MIG1206-xP-32 is a hybrid generator with two voltage wave shapes; 1,2/50µs at "no load" and a current wave form 8/20µs at short circuit. An integrated automatic coupling/de-coupling network completes the system.

Waveforms: CWG 1.2/50 µs, 8/20 µs (12 kV, 6 kA)
enlarge
Coupling: 1-Phase:
L-PE, N-PE, L-N
3-Phase:
L1-PE, L2-PE, L3-PE, N-PE
L1-L2, L2-L3, L1-L3, L1-N, L2-N, L3-N
L1 + L2 or L1 + L3 etc. to any other line
Current:
32Aac
25Adc
Standards: IEC61000-4-5
ANSI C62.41
IEC61643-1
IEC60060-1
Accessories: TC-MIG24 HL test cabinet:
High voltage outputs on front of MIG1206-xP-32
Component and circuit test up to 12kV within the test cabinet

enlarge
CDN-UTP (4 lines) and CDN-UTP8 (8 lines) telecom coupling de-coupling filters: CWG and 10/700µs - surge coupling onto data lines up to 6kV
Application for high speed telecom connections

enlarge


For more information please contact the representative in your region.