Lightning Tests: Military Equipment

Below you find short descriptions of EMC PARTNER's products for tests on military equipment.

Several immunity testers from the aircraft and the telecommunication fields can also be used to carry out tests on military equipment. In addition, EMC PARTNER is continuously extending its product range for military applications. In case of specific questions please do not hesitate to contact EMC PARTNER directly.


MIG2000-6

Control: MIG2000-6: Mainframe with control and high voltage supply for plug-ins CS106, CS115 and CS116
enlarge
Plug-ins:
(Range)
CS115REC (current 1.00 up to 15.0A)
CS116-10k..10M (depending on frequency 0.02 A up to 15.0 A)
CS116-30M+100M (depending on frequency 0.4 up to 11 A)
DC-S17-CL (coupling and decoupling networks for AC up to 400Hz)
CS106 (Voltage up to 400V)
Standards: MIL-STD-461E CS106, CS115 and CS116
Required Accessories:
(Range)
CN-MIG-BT (coupler for the frequency range 10 kHz up to 10 MHz
CN-MIG-BT2 (coupler for the frequency range 10 up to 100 MHz)
VERI-MIL2 (calibration fixture for the whole frequency range)
Accessories: Plug-ins:
NATO SPE-J-00-E-1000 FAST
NATO SPE-J-00-E-1000 SLOW
DO160 SECTION 17 Voltage Spike
DO160 SECTION 19 Induced Susceptibility
MIL-STD-1275B Imported Spikes
AMD-24C Voltage Spike
Customised:
with customised frequency (platform resonances)
TEMA: Windows based software for MIG2000 system
Optical link: Serial,optical connection between PC and Generator

enlarge

 

For more information please have a look at

MIG1212EMP and DN-MIG12-16

Outstanding features of the MIG1212EMP and the DN-MIG12-16 are:


Waveforms (Range): Common mode data of one generator:
voltage: 0.5/250 µs, (1 up to 10kV)
current: 0.5/250 µs, (50 up to 300 A)
Differential mode per generator:
voltage: 0.5/50 µs, (1 up to 10kV)
current: 0.5/50 µs, (50 up to 300 A)


enlarge
Control: Local or remote control (RS232) via optical link

Coupling: a.c. three phases 16 A / 440 V, neutral and protective earth

Standards: Customer recommendation IEC 61000-4-5 partly

Required Accessories: Decoupling: DN-MIG12-16
Software: TEMA
Calibration loads:
voltage NW-EUT-V
current NW-EUT-A
Optical link


 

For more information please have a look at