Below you find short descriptions of EMC PARTNER's products for tests on military equipment.
Several immunity testers from the aircraft and the telecommunication fields can also be used to carry out tests on military equipment. In addition, EMC PARTNER is continuously extending its product range for military applications. In case of specific questions please do not hesitate to contact EMC PARTNER directly.
| Control: | MIG2000-6: Mainframe with control and high voltage supply for plug-ins CS106, CS115 and CS116 | ![]() enlarge |
| Plug-ins: (Range) |
CS115REC (current 1.00 up to 15.0A) CS116-10k..10M (depending on frequency 0.02 A up to 15.0 A) CS116-30M+100M (depending on frequency 0.4 up to 11 A) DC-S17-CL (coupling and decoupling networks for AC up to 400Hz) CS106 (Voltage up to 400V) |
|
| Standards: | MIL-STD-461E CS106, CS115 and CS116 | |
| Required Accessories: (Range) |
CN-MIG-BT (coupler for the frequency range 10 kHz up to 10 MHz CN-MIG-BT2 (coupler for the frequency range 10 up to 100 MHz) VERI-MIL2 (calibration fixture for the whole frequency range) |
|
| Accessories: | Plug-ins: NATO SPE-J-00-E-1000 FAST NATO SPE-J-00-E-1000 SLOW DO160 SECTION 17 Voltage Spike DO160 SECTION 19 Induced Susceptibility MIL-STD-1275B Imported Spikes AMD-24C Voltage Spike Customised: with customised frequency (platform resonances) TEMA: Windows based software for MIG2000 system Optical link: Serial,optical connection between PC and Generator |
![]() enlarge |
For more information please have a look at
Outstanding features of the MIG1212EMP and the DN-MIG12-16 are:
| Waveforms (Range): | Common mode data of one generator: voltage: 0.5/250 µs, (1 up to 10kV) current: 0.5/250 µs, (50 up to 300 A) Differential mode per generator: voltage: 0.5/50 µs, (1 up to 10kV) current: 0.5/50 µs, (50 up to 300 A) |
![]() enlarge |
| Control: | Local or remote control (RS232) via optical link |
|
| Coupling: | a.c. three phases 16 A / 440 V, neutral and protective earth |
|
| Standards: | Customer recommendation IEC 61000-4-5 partly |
|
| Required Accessories: | Decoupling: DN-MIG12-16 Software: TEMA Calibration loads: voltage NW-EUT-V current NW-EUT-A Optical link |
For more information please have a look at