Below you find a selection of EMC PARTNER's products for lightning tests on telecommunication equipment based on the following standards or recommendations:
| Waveforms (Range): | 10/700 µs (up to 6 kV) CWG 1.2/50, 8/20 µs (6 kV, 3kA) |
![]() enlarge |
| Coupling: | CWG 1.2/50, 8/20 µs only Power supply a.c. L-N 480 V/16 A Power supply a.c. L/N to PE 280 V Power supply d.c. 110 V/16 A |
|
| Standards: | ITU-T K.44, K.17, K.20, K.21, |
|
| Accessories: | see accessories for telecom coupling |
For more information please have a look at
| Waveform (Range): | CWG 1.2/50 µs, 8/20 µs (6 kV, 3 kA) 10/700 µs (up to 6 kV) 1.2/50 µs (up to 6 kV) |
![]() enlarge |
| Coupling: | a.c.: CWG 280 V/16 A d.c.: CWG 110 V/16 A |
|
| Standards: | IEC 61000-4-5, ITU-T K.44 10/700 µs, ITU-T K.21, IEC/EN 60950 | |
| Accessory: |
see accessories for telecom coupling |
For more information please have a look at
Ideal combination for EMC transient tests on telecom equipment.
| Waveforms: (Range) |
CWG 1.2/50, 8/20 µs (6 kV, 3 kA) 10/700 µs (up to 6 kV) 100kHz ring wave (up to 6 kV) EFT: 5/50 ns (up to 4.4 kV) ESD: CD/AD (up to 8 kV/15 kV) DIPS: all levels voltage and time |
![]() enlarge |
| Standards: | IEC 61000-4-11, IEC 61000-4-5, IEC 61000-4-4, |
|
| Coupling: | Power supply a.c. L-N 280V, 16 A Power supply a.c. L/N to PE 280V Power supply d.c. 110V, 16 A |
|
| Accessories: | see accessories for telecom coupling | |
| Further Accessories: | TEMA (Test Manager Software) CDN2000A-06-32, CN2000TT MC |
For more information please have a look at
The maximum test levels are specified in the ITU-T K.20 and K.21 documents:
| Waveforms: (Range) |
CWG 1.2/50, 8/20 µs (12 kV, 6 kA) | ![]() enlarge |
| Standards: | IEC 61000-4-5, ITU-T K.44, K.20, K.21 | |
| Coupling using CDN-MIG12-32: | Power supply a.c. L-L/N 480V, 32 A Power supply a.c. L/N to PE 280 V Power supply d.c. 280 V, 32 A |
|
| Accessories: | see accessories for telecom coupling | |
| Further Accessories: | TEMA (Test Manager Software) |
For more information please have a look at
The MIG1206-xP-T is a hybrid generator with two voltage wave shapes; 1,2/50µs at "no load" and a current wave form 8/20µs at short circuit combined with the 10/700µs "Telecom" impulse. An integrated automatic coupling/de-coupling network completes the system.
| Waveforms (Range): |
CWG 1.2/50 µs, 8/20 µs (12 kV/6 kA) Telecom Pulse: 10/700µs open circuit (up to 6 kV) |
![]() enlarge |
| Coupling: | 1-Phase L-PE, N-PE, L-N 3-Phase L1-PE, L2-PE, L3-PE, N-PE L1-L2, L2-L3, L1-L3, L1-N, L2-N, L3-N L1 + L2 or L1 + L3 etc. to any other line Current: 32Aac 25Adc |
|
| Standards: | IEC61000-4-5, ANSI C62.41, IEC61643-1, IEC60060-1, ITU-T K44, ITU-T K20, ITU-T K21 | |
| Accessories: | TC-MIG24 HL test cabinet: High voltage outputs on front of MIG1206-xP-32 Component and circuit test up to 12kV within the test cabinet |
enlarge |
| see also accessories for telecom coupling |
For more information please have a look at
| Waveform (Range): | 10/700 µs (up to 12 kV) | ![]() enlarge |
| Standards: | ITU-T K.44, ITU-T K.17, ITU-T K.20, |
|
| Options: | 1.2/50 µs up to 12 kV CWG up to 6 kV 10/1000µs up to 12 kV |
|
| Required Accessory: |
TC-MIG24 or CN-MIG24 |
For more information please have a look at
| Waveform (Range): | 8/20 µs (up to 24 kA) | ![]() enlarge |
| Coupling: | cable 1 m with test adaptor | |
| Standards: | ITU-T K.44, K.17, K.20, K.21 | |
| Options: | Resistor network | |
| Required Accessory: |
TC-MIG24 or CN-MIG24 |
For more information please have a look at
| Waveforms (Range): |
8/20µs (up to 12kA) 10/350µs (up to 4kA) 10/1000µs (up to 200A) |
enlarge |
| Standards: |
ITU-T K12 | |
| Required Accessories: | TC-MIG24 HL test cabinet | enlarge |
For more information please have a look at
| Waveforms (Range): |
8/20µs (up to 24kA) 10/350µs (up to 8kA) 10/1000µs (up to 400A) |
enlarge |
| Standards: |
ITU-T K12 | |
| Required Accessories: | TC-MIG24 HL test cabinet | enlarge |
For more information please have a look at
A device for power induction testing at frequencies of 50Hz and 60Hz
| Rating: | 50V up to 1690V continuous power up to 3.5kVA short time power up to 7kVA timer 0.1 up to 9.9s |
![]() enlarge |
| Coupling: |
2 x 200 Ohm 2 x 600 Ohm |
For more information please have a look at
Accessory to the TRA2000 with DIP circuit.
NW-K44PC enables power contact testing at frequencies of 50Hz and 60Hz.
| Power Contact: | Rating: | 230V up to 23A | ![]() enlarge |
| Coupling: | 2 x 300 ohm 2 x 600 ohm 2 x 1000 ohm 2 x 1200 ohm |
||
| Option: |
TRA OPTION NW-K44PI |
For more information please have a look at
Option to NW-K44PC.
| Power induction network includes transformer and current limiting resistors. | enlarge |
|
| Accessories: |
PCPI160E | |
For more information please have a look at
| Waveforms (Range): | CWG 1.2/50 µs, 8/20 µs (6 kV, 3 kA) 9/720 µs, 5/320 µs (6 kV, 150 A) 10/160 µs, 10/160 µs (1500 V, 200 A) 10/560 µs, 10/560 µs (800 V, 100 A) 2/10 µs, 2/10 µs (2500 V, 1000 A) |
![]() enlarge |
|
| Coupling: | a.c.: | CWG, 280 V/16 A 2/10 µs, 280 V/16 A |
|
| d.c.: | CWG, 110 V/ 16 A 2/10 µs, 110 V/16 A |
||
| Standards: | IEC 61000-4-5, ITU-T K.44, |
||
| Accessories: | see accessories for telecom coupling | ||
For more information please have a look at
The CDN-UTP (4 lines) and the CDN-UTP8 (8 lines) are sophisticated coupling and de-coupling networks for superimposing surge impulses on balanced communication lines in accordance with IEC61000-4-5, ITU-K20, K21 and FCC part 68. The CDN-UTP and CDN-UTP8 are specially designed to fulfil the requirements of modern high speed communication systems.
| Rating: | Surge 1.2/50, 8/20 µs: max. 6.6 kV Surge 10/700 µs: max. 6.0 kV |
![]() enlarge |
| Application: | tested and recommended: - Analogue subscriber lines (a/b-line) - ISDN - ADSL resp. xDSL - Ethernet: 10Base-T - USB - Interbus - Profibus - ASI = Actor Sensor Interface |
|
| Standards: | IEC 61000-4-5, FCC part 68, ITU-K.44, |
|
| Coupling: | - direct - via 90V gas arrestor (GTD) - via 90V gas arrestor // 100nF - via 66V clamping diode - different resistors: 25, 50, 100, 80, 100 Ohm |
|
| De-coupling: | - common mode inductance 20 mH - d.c. resistance 3.5 Ohm max. unbalanced 0.003 Ohm |
|
| Can be used with generators: | TRA2000IN4, TRA2000IN6, MIG0603IN2, MIG0603IN3, MIG0603EN, MIG0603FCC |
The CDN-KIT1000 is a universal coupling/de-coupling kit for unbalanced telecom and communication lines.
| Rating: | Surge 1.2/50, 8/20 µs: max. 6 kV Surge 10/700 µs: max. 6 kV |
![]() enlarge |
| Application: | unshielded and unbalanced telecom lines | |
| Standards: | IEC 61000-4-5, FCC part 68, ITU-K.44, |
|
| Coupling: | - direct - via 0.5µF and 40 Ohm resistor |
|
| De-coupling: | - clamping diode 27 V - clamping diode 54 V - clamping diode 81 V - direct 220 V |
|
| Can be used with generators: | TRA2000IN4, TRA2000IN6, MIG0603IN2, MIG0603IN3, MIG0603EN, MIG0603FCC |
The CN10-700E25 is a specialist coupling unit for telecom testing.
| Rating: | Surge 1.2/50, 8/20 µs: max. 6 kV Surge 10/700 µs: max. 6 kV |
![]() enlarge |
| Application: | balanced and unbalanced telecom lines | |
| Standards: | ITU-K.44, |
|
| Coupling: | 2 x 25 Ohm coupling with 90 V GDT | |
| Can be used with generators: | TRA2000IN4, TRA2000IN6, MIG0603IN2, MIG0603IN3, MIG0603EN, MIG0603FCC |
For more information please have a look at