Below you find short descriptions of EMC PARTNER's One Box EMC Test Stations:
| Waveforms (Range): | ESD (8/15 kV), EFT (4 kV), SURGE (4,1 kV), DIPS |
|
| Coupling: | a.c.: single phase 16 A/260 V d.c.: 16 A/110 V |
|
| Standards: | IEC 61000-4-2, -4, -5, -8, -9, -11, -16, -29 | |
| Required Accessory: |
ESD Mouse CNEFT1000 coupling clamp |
For more information please have a look at
| Waveforms (Range): | ESD (8/15 kV), EFT (4 kV), Surge (4 kV), DIPS |
![]() enlarge |
| Coupling: | a.c.: for single phase 16 A/260 V d.c.: 16 A/110 V |
|
| Standards: | IEC 61000-4-2, -4, -5, -8, -9, |
|
| Required Accessory: |
ESD-Mouse CNEFT1000 |
For more information please
| Waveform (Range): | ESD (8/15 kV), EFT (4 kV), Surge |
![]() enlarge |
| Coupling: | a.c.: single phase 16 A/260 V d.c.: 16 A/110 V |
|
| Standards: | IEC/EN 61000-4-2, -4, -5, -8, -9, -11, -12, -16, -29, ANSI/IEEE C62.41, ANSI/IEEE C62.45 | |
| Options: | Option 10/100 Option External CDN coupling Option Diagnostic 1P |
|
| Required Accessory: | ESD Mouse CNEFT1000 |
For more information please have a look at
| Rating: | Supply Voltage (a.c. or d.c.): L to N/PE 240 V, L to L 480 V Supply Current: Continuous operation (a.c. or d.c.): Continuous operation (d.c.): Test Voltages: Surge voltage: maximum 6.6 kV Ring voltage: maximum 6.6 kV EFT voltage: maximum 6.3 kV |
![]() enlarge ![]() enlarge ![]() enlarge |
| Control: |
RS232 connection from the rear side of the TRA2000 or MIG0603INx to the CDN2000A-06-32 For the selection of the coupling paths see the displays on the right. Power supply: 90 to 240 V and 50/60Hz |
|
| Standards: | IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4 |
|
| Option: | 480V: for power supply L to N/PE 280 V and L to L 480 V |
|
| For use with these generators: | TRA2000, TRA2000IN4, TRA2000IN6, MIG0603IN, MIG0603IN1, MIG0603IN3, MIG0603IN4 |
For more information please have a look at