Harmonic Emission - IEC 1000-3-2 , EN 61000-3-2 , (EN60555-2)

Comply: IEC 61000-3-2 Ed.2.1 :2001 (incl. Amd.14) - IEC 61000-4-7 Ed.1.0 :1991


EMC PARTNER AG, SWITZERLAND
www.emc-partner.com


HARCS Setup File :
D:\HARCS\EXAMPLES\mon-sim.hsu
HARCS Report File :
D:\HARCS\EXAMPLES\mon-sim.HRP

Operator :      		R.Casanova
Unit :          		Simulation of a 17"-PC-Monitor
Serialnumber :  		
Bemerkungen :   		



   Full Bar  : Actual Values
   Empty Bar : Maximum Values
   Blue : Current , Green : Voltage , Red : Failed


Notes
Simulation of a 17"-PC-Monitor
==============================

Basis for this simulation is a real measurement on a  
PHILLIPS 17"-Monitor (see example "monitor-crt17inch").

The equivalent circuit is already evaluated by the ANASIM software.
Under : (Option/Simulation/SIM)
- the blue curve shows the current of the equivalent circuit.
- the black curve shows the current of the original monitor.

The harmonic currents are far over the limits for class-D.
By increasing the series resistor it is possible to decrease
the harmonics under the limits. Try 40ohm.

Choose : (Option/Simulation/SIM)

Press "Run Simulation" to get the new result


Here the simulation after inserting 40ohm in series