Flicker Emission - IEC 1000-3-3 , EN 61000-3-3 , (EN60555-3)
Comply: IEC 61000-3-3 Ed.1.1 :2002 (incl. Amd.1) - IEC 61000-4-15 Ed.1.0 :1997 (incl. Amd.1)
EMC PARTNER AG, SWITZERLAND
HARCS Setup File :
Operator : R.Casanova Unit : Washing machine : CANDY Serialnumber : unknown Bemerkungen : Within the limits
Measurement Date : 22.08.02 00:40:31 V3.10 Urms = 229.7V Freq = 50.016 Range: 25 A Irms = 0.037A Ipk = 0.098A cf = 2.667 P = 1.841W Pap = 8.412VA pf = 0.219 Test - Time : 12 x 10min = 120min ( 100 %) LIN (Line Impedance Network) : SLIN 0.24ohm +j0.15ohm N:0.16ohm +j0.10ohm Limits : Plt : 0.65 Pst : 1.00 dmax : 4.00 % dc : 3.00 % dtLim: 3.00 % dt>Lim: 200ms Test completed, Result: PASSED Plt = 0.447 Pst P50s P10s P3s P1s P0.1s dmax dc dt>Lim [%] [%] [ms] 1 0.615 0.010 0.098 0.375 0.698 9.207 2.790 2.160 0.000 2 0.321 0.010 0.029 0.186 0.333 2.054 1.820 1.800 0.000 3 0.283 0.010 0.042 0.257 0.449 0.869 1.790 0.390 0.000 4 0.345 0.012 0.147 0.326 0.468 0.980 1.920 0.830 0.000 5 0.373 0.010 0.122 0.340 0.571 1.649 1.910 0.840 0.000 6 0.381 0.010 0.106 0.340 0.607 1.935 2.260 0.720 0.000 7 0.800 0.010 0.118 0.449 1.150 16.44 3.330 0.410 40.00 8 0.486 0.010 0.120 0.368 0.657 4.572 2.480 0.950 0.000 9 0.163 0.010 0.010 0.049 0.141 0.391 1.470 0.390 0.000 10 0.072 0.010 0.010 0.010 0.010 0.010 0.000 0.020 0.000 11 0.072 0.010 0.010 0.010 0.010 0.010 0.030 0.020 0.000 12 0.072 0.010 0.010 0.010 0.010 0.010 0.000 0.020 0.000
Definitions of Abbreviations
Urms *** Actual total Voltage in Volt RMS
Irms *** Actual total Current in Ampere RMS
Ipk *** Actual Peak value of the Current in Ampere
cf *** Actual Crest Factor (Ipk/Irms)
P *** Actual Active Power in Watt
Pap *** Actual Apparent Power in VA (Urms*Irms)
pf *** Actual Power Factor (P/Pap)
Plt Long term Flicker over all Pst cycles
For every Pst-cycle:
Pst Short term Flicker
P50s Flicker level reached during 50% of the test time
P10s Flicker level reached during 10% of the test time
P3s Flicker level reached during 3% of the test time
P1s Flicker level reached during 1% of the test time
P0.1s Flicker level reached during 0.1% of the test time
dmax Maximum voltage changes between two steady state conditions
dc Voltage changes between two steady conditions
dt>Lim Time during the voltage variation go to across
the defined limit (dtlim)
General :
- The values marked with "***" are actual values which could vary
during test-time and are taken at the time of protocol printout.
Notes Flicker measurements on waching machine CANDY ============================================= The washing machine is tested in the 60°C laundry program. It is filled with a normal load of cloths as specified in IEC60335-2-7. The test-time is 12 x 10 minutes. The 60°C program takes 95 minutes. The heater draws about 2000W, the motor between 150W and 300W with peaks up to 400W. The PST is high during the heating and drying. All vaues are below the limits.
Recorder : active Power P