IEC 1000-3-3 : Flicker Simulation for an Heater Group
First Step:
Choose Options / Simulation / SIM to change to simulation mode
Second Step:
Enter the Power versus Time values into the table

Last Step :
Run the Flicker test as usual and you get the results like or a real measurement. Below you see the protocol as automatically generated in HTML mode.
Flicker Emission - IEC 1000-3-3 , EN 61000-3-3 , (EN60555-3)
Comply : IEC 1000-3-3 A1: 2002 -- IEC 1004-15 A1 : 2002
EMC PARTNER AG, SWITZERLAND
HARCS Setup File :
Operator : R.Casanova Unit : 2*750W Heater Serialnumber : none Bemerkungen : simultaneosly switched
Full Bar : Actual Values
Empty Bar : Maximum Values
Circles : Average Values
Blue : Current , Green : Voltage , Red : Failed
Measurement
Date : 08.08.02 15:49:13 V3.10
Test - Time : 1 x 3min = 3min ( 100 %)
LIN (Line Impedance Network) :
SLIN 0.24ohm +j0.15ohm N:0.16ohm +j0.10ohmLimits : Plt : 0.65 Pst : 1.00 dmax : 4.00 % dc : 3.00 % dtLim: 3.00 % dt>Lim: 200ms Flicker Simulation Pst P50s P10s P3s P1s P0.1s Fli(m) 1 1.085 0.016 1.271 4.572 6.050 6.424 6.509
Definitions of Abbreviations Plt Long term Flicker over all Pst cycles For every Pst-cycle: Pst Short term Flicker P50s Flicker level reached during 50% of the test time P10s Flicker level reached during 10% of the test time P3s Flicker level reached during 3% of the test time P1s Flicker level reached during 1% of the test time P0.1s Flicker level reached during 0.1% of the test time Fli(max) Maximum Flicker level during test time General : - The values marked with "***" are actual values which could vary during test-time and are taken at the time of protocol printout.
Notes 1500W Heater Group ------------------ Two heater of 750W each are switched on every 10 second for 5 second. The resulting Short-Term Flicker (Pst) is higher than 1.00