IEC 1000-3-3 : Flicker Simulation for an Heater Group
The "ANASIM" Software with the Flicker simulation offers the possibilities to calculate in advance the Flicker of a circuit. Today no other software can be found on the market for Flicker simulation. The "ANASIM" software is a sophisticated tool for design and test engineers.
The basis for the simulation is the time function of the apparent input power and the power factor of the EUT.

First Step:

Choose Options / Simulation / SIM to change to simulation mode

Second Step:

Enter the Power versus Time values into the table

Last Step :

Run the Flicker test as usual and you get the results like or a real measurement. Below you see the protocol as automatically generated in HTML mode.

 


Flicker Emission - IEC 1000-3-3 , EN 61000-3-3 , (EN60555-3)

Comply :  IEC 1000-3-3  A1: 2002 -- IEC 1004-15  A1 : 2002


EMC PARTNER AG, SWITZERLAND
www.emc-partner.com


HARCS Setup File :
D:\HARCS\EXAMPLES\heater1.hsu
HARCS Report File :
D:\HARCS\heater1.HRP.hrp

Operator :      		R.Casanova
Unit :          		2*750W Heater
Serialnumber :  		none
Bemerkungen :   		simultaneosly switched



   Full Bar  : Actual Values
   Empty Bar : Maximum Values
   Circles   : Average Values
   Blue : Current , Green : Voltage , Red : Failed


Measurement
                                            Date : 08.08.02 15:49:13 V3.10

Test - Time :	1 x 3min = 3min	( 100 %)

LIN (Line Impedance Network) : SLIN 0.24ohm +j0.15ohm N:0.16ohm +j0.10ohm


Limits :	Plt  :	0.65	Pst   :	1.00	
		dmax :	4.00 %	dc    :	3.00 %	
		dtLim:	3.00 %	dt>Lim:	200ms	

Flicker Simulation

 	Pst	P50s	P10s	P3s	P1s	P0.1s	Fli(m)	
 	 	 	 	 	 	 	 	
1	1.085	0.016	1.271	4.572	6.050	6.424	6.509	


Definitions of Abbreviations
Plt             Long term Flicker over all Pst cycles

For every Pst-cycle:

Pst             Short term Flicker
P50s            Flicker level reached during 50% of the test time
P10s            Flicker level reached during 10% of the test time
P3s             Flicker level reached during 3% of the test time
P1s             Flicker level reached during 1% of the test time
P0.1s           Flicker level reached during 0.1% of the test time
Fli(max)        Maximum Flicker level during test time

General :
- The values marked with "***" are actual values which could vary
  during test-time and are taken at the time of protocol printout.


Notes
1500W Heater Group
------------------
Two heater of 750W each are switched on every 10 second for 5 second.

The resulting Short-Term Flicker (Pst) is higher than 1.00