Insulation Test on 36pol HCX Connector ( Pin to Pin )
EMC-PARTNER AG, 4242 Laufen, Switzerland
TEMA Sequence File : Examples\more\connector-test.SEQ
Operator : |
R.Casanova |
Unit : |
HCX-36p |
17:34 06.08.02 |
  |
Serial Nbr.: |
2455-436 |
This sample has FAILED
Port  V-peak  I-Peak  Status  Result      H1->L2  + 6058V  + 4A  pass        H1->L2  - 5769V  - 4A  pass        H2->L3  + 6054V  + 4A  pass        H2->L3  - 5737V  - 4A  pass        H3->L4  + 6068V  + 4A  pass        H3->L4  - 5711V  - 4A  pass        H4->L5  + 6034V  + 4A  pass        H4->L5  - 5717V  - 4A  pass        H5->L6  + 6109V  + 4A  pass        H5->L6  - 5759V  - 4A  pass        H6->L7  + 6075V  + 191A  fail  191A > 100A      H6->L7  - 5756V  - 186A  fail  186A > 100A      H7->L8  + 6058V  + 190A  fail  190A > 100A      H7->L8  - 5743V  - 194A  fail  194A > 100A      H8->L9  + 6105V  + 4A  pass        H8->L9  - 5746V  - 4A  pass        H9->L10  + 6109V  + 4A  pass        H9->L10  - 5740V  - 4A  pass        H10->L11  + 6061V  + 4A  pass        H10->L11  - 5772V  - 4A  pass        H11->L12  + 6061V  + 4A  pass        H11->L12  - 5753V  - 4A  pass        H12->L13  + 6095V  + 4A  pass        H12->L13  - 5750V  - 4A  pass        H13->L14  + 6085V  + 4A  pass        H13->L14  - 5750V  - 4A  pass        H14->L15  + 6085V  + 4A  pass        H14->L15  - 5762V  - 4A  pass        H15->L16  + 6116V  + 4A  pass        H15->L16  - 5756V  - 4A  pass        H16->L17  + 6037V  + 4A  pass        H16->L17  - 5724V  - 4A  pass        H17->L18  + 6075V  + 4A  pass        H17->L18  - 5762V  - 4A  pass        H18->L19  + 6078V  + 4A  pass        H18->L19  - 5737V  - 4A  pass        H19->L20  + 6085V  + 4A  pass        H19->L20  - 5727V  - 4A  pass        H20->L21  + 6095V  + 4A  pass        H20->L21  - 5730V  - 4A  pass        H21->L22  + 6095V  + 4A  pass        H21->L22  - 5705V  - 4A  pass        H22->L23  + 6048V  + 4A  pass        H22->L23  - 5724V  - 4A  pass        H23->L24  + 6061V  + 4A  pass        H23->L24  - 5727V  - 4A  pass        H24->L25  + 6071V  + 4A  pass        H24->L25  - 5743V  - 4A  pass        H25->L26  + 6071V  + 4A  pass        H25->L26  - 5737V  - 4A  pass        H26->L27  + 6105V  + 4A  pass        H26->L27  + 6105V  + 4A  pass        H27->L28  + 6041V  + 4A  pass        H27->L28  - 5762V  - 4A  pass        H28->L29  + 6085V  + 4A  pass        H28->L29  - 5753V  - 4A  pass        H29->L30  + 6051V  + 4A  pass        H29->L30  - 5769V  - 4A  pass        H30->L31  + 6061V  + 4A  pass        H30->L31  - 5721V  - 4A  pass        H31->L32  + 6095V  + 4A  pass        H31->L32  - 5750V  - 4A  pass        H32->L33  + 6054V  + 4A  pass        H32->L33  - 5730V  - 4A  pass        H33->L34  + 6082V  + 4A  pass        H33->L34  - 5769V  - 4A  pass        H34->L35  + 6082V  + 4A  pass        H34->L35  - 5746V  - 4A  pass        H35->L36  + 6071V  + 4A  pass        H35->L36  - 5730V  - 4A  pass       
Test-Report
Notes
On the 36pol HCX connector all neighbouring pins have to be tested with an 6kV
1.2/50us pulse of both polarities. The full automatic test set-up uses a pulse
generator, an automatic switching box and the TEMA software.
The interval between two pulses is about 10sec and the overall time for all
pins about 15min. The insulation test has failed if any current higher than
100Apeak is measured. This is detected with the internal peak measurement of
the generator.
Equipment used:
MIG1203 - 12kV pulse generator EMC-PARTNER
MIGCOMAT - Coupling Matrix EMC-PARTNER
TEMA Software EMC-PARTNER
The MIGCOMAT Coupling Matrix is controlled by a the following text-file:
........................................................................
; File Migcomat-HCX36p.txt
; -------------------------
;
; select every pair
;
;H1->L2 ; is set by first block
H2->L3
H3->L4
H4->L5
H5->L6
H6->L7
H7->L8
H8->L9
H9->L10
H10->L11
H11->L12
H12->L13
H13->L14
H14->L15
H15->L16
H16->L17
H17->L18
H18->L19
H19->L20
H20->L21
H21->L22
H22->L23
H23->L24
H24->L25
H25->L26
H26->L27
H27->L28
H28->L29
H29->L30
H30->L31
H31->L32
H32->L33
H33->L34
H34->L35
H35->L36
........................................................................