Insulation Test on 36pol HCX Connector ( Pin to Pin )

EMC-PARTNER AG, 4242 Laufen, Switzerland

TEMA Sequence File : Examples\more\connector-test.SEQ

Operator :

R.Casanova

Unit :

HCX-36p

17:34 06.08.02

 

Serial Nbr.:

2455-436

This sample has FAILED





Test-Report

Port 

V-peak 

I-Peak 

Status 

Result 

 

 

H1->L2 

+ 6058V 

+ 4A 

pass 

 

 

 

H1->L2 

- 5769V 

- 4A 

pass 

 

 

 

H2->L3 

+ 6054V 

+ 4A 

pass 

 

 

 

H2->L3 

- 5737V 

- 4A 

pass 

 

 

 

H3->L4 

+ 6068V 

+ 4A 

pass 

 

 

 

H3->L4 

- 5711V 

- 4A 

pass 

 

 

 

H4->L5 

+ 6034V 

+ 4A 

pass 

 

 

 

H4->L5 

- 5717V 

- 4A 

pass 

 

 

 

H5->L6 

+ 6109V 

+ 4A 

pass 

 

 

 

H5->L6 

- 5759V 

- 4A 

pass 

 

 

 

H6->L7 

+ 6075V 

+ 191A 

fail 

191A > 100A 

 

 

H6->L7 

- 5756V 

- 186A 

fail 

186A > 100A 

 

 

H7->L8 

+ 6058V 

+ 190A 

fail 

190A > 100A 

 

 

H7->L8 

- 5743V 

- 194A 

fail 

194A > 100A 

 

 

H8->L9 

+ 6105V 

+ 4A 

pass 

 

 

 

H8->L9 

- 5746V 

- 4A 

pass 

 

 

 

H9->L10 

+ 6109V 

+ 4A 

pass 

 

 

 

H9->L10 

- 5740V 

- 4A 

pass 

 

 

 

H10->L11 

+ 6061V 

+ 4A 

pass 

 

 

 

H10->L11 

- 5772V 

- 4A 

pass 

 

 

 

H11->L12 

+ 6061V 

+ 4A 

pass 

 

 

 

H11->L12 

- 5753V 

- 4A 

pass 

 

 

 

H12->L13 

+ 6095V 

+ 4A 

pass 

 

 

 

H12->L13 

- 5750V 

- 4A 

pass 

 

 

 

H13->L14 

+ 6085V 

+ 4A 

pass 

 

 

 

H13->L14 

- 5750V 

- 4A 

pass 

 

 

 

H14->L15 

+ 6085V 

+ 4A 

pass 

 

 

 

H14->L15 

- 5762V 

- 4A 

pass 

 

 

 

H15->L16 

+ 6116V 

+ 4A 

pass 

 

 

 

H15->L16 

- 5756V 

- 4A 

pass 

 

 

 

H16->L17 

+ 6037V 

+ 4A 

pass 

 

 

 

H16->L17 

- 5724V 

- 4A 

pass 

 

 

 

H17->L18 

+ 6075V 

+ 4A 

pass 

 

 

 

H17->L18 

- 5762V 

- 4A 

pass 

 

 

 

H18->L19 

+ 6078V 

+ 4A 

pass 

 

 

 

H18->L19 

- 5737V 

- 4A 

pass 

 

 

 

H19->L20 

+ 6085V 

+ 4A 

pass 

 

 

 

H19->L20 

- 5727V 

- 4A 

pass 

 

 

 

H20->L21 

+ 6095V 

+ 4A 

pass 

 

 

 

H20->L21 

- 5730V 

- 4A 

pass 

 

 

 

H21->L22 

+ 6095V 

+ 4A 

pass 

 

 

 

H21->L22 

- 5705V 

- 4A 

pass 

 

 

 

H22->L23 

+ 6048V 

+ 4A 

pass 

 

 

 

H22->L23 

- 5724V 

- 4A 

pass 

 

 

 

H23->L24 

+ 6061V 

+ 4A 

pass 

 

 

 

H23->L24 

- 5727V 

- 4A 

pass 

 

 

 

H24->L25 

+ 6071V 

+ 4A 

pass 

 

 

 

H24->L25 

- 5743V 

- 4A 

pass 

 

 

 

H25->L26 

+ 6071V 

+ 4A 

pass 

 

 

 

H25->L26 

- 5737V 

- 4A 

pass 

 

 

 

H26->L27 

+ 6105V 

+ 4A 

pass 

 

 

 

H26->L27 

+ 6105V 

+ 4A 

pass 

 

 

 

H27->L28 

+ 6041V 

+ 4A 

pass 

 

 

 

H27->L28 

- 5762V 

- 4A 

pass 

 

 

 

H28->L29 

+ 6085V 

+ 4A 

pass 

 

 

 

H28->L29 

- 5753V 

- 4A 

pass 

 

 

 

H29->L30 

+ 6051V 

+ 4A 

pass 

 

 

 

H29->L30 

- 5769V 

- 4A 

pass 

 

 

 

H30->L31 

+ 6061V 

+ 4A 

pass 

 

 

 

H30->L31 

- 5721V 

- 4A 

pass 

 

 

 

H31->L32 

+ 6095V 

+ 4A 

pass 

 

 

 

H31->L32 

- 5750V 

- 4A 

pass 

 

 

 

H32->L33 

+ 6054V 

+ 4A 

pass 

 

 

 

H32->L33 

- 5730V 

- 4A 

pass 

 

 

 

H33->L34 

+ 6082V 

+ 4A 

pass 

 

 

 

H33->L34 

- 5769V 

- 4A 

pass 

 

 

 

H34->L35 

+ 6082V 

+ 4A 

pass 

 

 

 

H34->L35 

- 5746V 

- 4A 

pass 

 

 

 

H35->L36 

+ 6071V 

+ 4A 

pass 

 

 

 

H35->L36 

- 5730V 

- 4A 

pass 

 

 

 





Notes

On the 36pol HCX connector all neighbouring pins have to be tested with an 6kV
1.2/50us pulse of both polarities. The full automatic test set-up uses a pulse
generator, an automatic switching box and the TEMA software.

The interval between two pulses is about 10sec and the overall time for all
pins about 15min. The insulation test has failed if any current higher than
100Apeak is measured. This is detected with the internal peak measurement of
the generator.

Equipment used:
 MIG1203 - 12kV pulse generator  EMC-PARTNER
 MIGCOMAT - Coupling Matrix      EMC-PARTNER
 TEMA Software                   EMC-PARTNER


The MIGCOMAT Coupling Matrix is controlled by a the following text-file:
........................................................................

; File Migcomat-HCX36p.txt
; -------------------------
;
; select every pair
;
;H1->L2  ; is set by first block
H2->L3
H3->L4
H4->L5
H5->L6
H6->L7
H7->L8
H8->L9
H9->L10
H10->L11
H11->L12
H12->L13
H13->L14
H14->L15
H15->L16
H16->L17
H17->L18
H18->L19
H19->L20
H20->L21
H21->L22
H22->L23
H23->L24
H24->L25
H25->L26
H26->L27
H27->L28
H28->L29
H29->L30
H30->L31
H31->L32
H32->L33
H33->L34
H34->L35
H35->L36
........................................................................