Version : 21.03.03 , based on 61000-4-5 IEC:200X
EMC-Partner Generator : Overview
2. Exposure Classes
3. Test Levels, Combination wave
3.1. CWG : Power supply
3.2. CWG : Unbalanced operated datalines, LDB
( LDB = long-distance bus )
3.3. CWG : Balanced operated datalines
3.4. CWG : SDB and DB ( SDB = short-distance
bus , DB = databus, dataline )
4. Test Levels, 10/700us ( for ports of long distance )
4.1. 10/700us : Balanced operated
datalines
The Basic EMC Standards for Surge define the methods of generating consistently reproducible surge voltages for test purposes. They specify generator and coupler/decoupler design and performance in sufficient detail to produce correlatable results between test sites.
While the Basic EMC Standard specifies how to perform Surge testing, the Generic, Product and Product Family Standards specify the test levels and pass/fail performance criteria.
IEC 61000-4-5 also includes climatic specification as follows:
Ambient temperature :
15°C to
35°C
Relative Humidity :
10% to 75%
Atmospheric Pressure :
86kPa (860 mbar)
to 106kPa (1060 mbar)
Other values may be specified in the test specification.
The surge test can be destructive to the EUT if adequate protection is not incorporated into the design. Therefore, this test should be carried out only after a successful burst ( EFT ) test.
The test level is set by the European Norms (EN) as a function of use and exposure class.
Class |
Description |
0 |
Well-protected electrical environment, often within a special room |
1 |
Partly protected electrical environment |
2 |
Electrical environment where cables are well separated, even at short runs |
3 |
Electrical environment where cables run in parallel |
4 |
Electrical environment where the interconnections are running as outdoor cables along with power cables, and cables are used for both electronic and electric circuits. |
5 |
Electrical environment for electronic equipment connected to telecomunication cables and overhead power lines in a non-densely populated area |
X |
Special conditions specified in the product specification |
Class |
Test levels ( kV ) |
AC power
supply, |
AC power
supply, |
|||
Line to line |
Line to earth |
TEMA setup |
Example |
TEMA setup |
Example |
|
0 |
NA |
NA |
--- |
--- |
--- |
--- |
1 |
NA |
0.5 |
||||
2 |
0.5 |
1.0 |
||||
3 |
1.0 |
2.0 |
||||
4 |
2.0 |
4.0 (3) |
||||
5 |
(2) |
(2) |
||||
X |
||||||
| Equipment | Generator only | Generator + CDN2000A 3ph-Coupler |
||||
(2) Depends on the class of the local power supply system
(3) Normally tested with primary protection
NA : not applicable
For each coupling path 5 pulses positive and 5 pulses negative at each 0°, 90°, 180°
and 270° are applied.
All lower levels including the selected test level are tested.
Class |
Test levels ( kV ) |
Line to line |
Line to earth |
|||
Line to line |
Line to earth |
TEMA setup |
Example |
TEMA setup |
Example |
|
0 |
NA |
NA |
--- |
--- |
--- |
--- |
1 |
NA |
0.5 |
--- |
--- |
||
2 |
0.5 |
1.0 |
||||
3 |
1.0 |
2.0 (3) |
||||
4 |
2.0 |
4.0 (3) |
||||
5 |
2.0 |
4.0 (3) |
||||
X |
||||||
| Equipment | Generator + CDNKIT Coupling Set | |||||
(3) Normally tested with primary protection
5 pulses positive and 5 pulses negative are applied.
All lower levels including the selected test level are tested.
Class |
Test levels ( kV ) |
Line to line |
Line to earth |
|||
Line to line |
Line to earth |
TEMA setup |
Example |
TEMA setup |
Example |
|
0 |
NA |
NA |
--- |
--- |
--- |
--- |
1 |
NA |
0.5 |
--- |
--- |
||
2 |
NA |
1.0 |
--- |
--- |
||
3 |
NA |
2.0 (3) |
--- |
--- |
||
4 |
NA |
2.0 (3) |
--- |
--- |
||
5 |
NA |
4.0 (3) |
--- |
--- |
||
X |
||||||
| Equipment | Generator + CDN-UTP Balanced Coupler | |||||
(3) Normally tested with primary protection
5 pulses positive and 5 pulses negative are applied.
All lower levels including the selected test level are tested.
Class |
Test levels ( kV ) |
Line to line |
Line to earth |
|||
Line to line |
Line to earth |
TEMA setup |
Example |
TEMA setup |
Example |
|
0 |
NA |
NA |
--- |
--- |
--- |
--- |
1 |
NA |
NA |
--- |
--- |
--- |
--- |
2 |
NA |
0.5 |
--- |
--- |
||
3 |
NA |
NA |
--- |
--- |
--- |
--- |
4 |
NA |
NA |
--- |
--- |
--- |
--- |
5 |
NA |
NA |
--- |
--- |
--- |
--- |
X |
--- |
--- |
--- |
--- |
||
| Equipment | Generator + CDNKIT Coupling Set | |||||
5 pulses positive and 5 pulses negative are applied.
All lower levels including the selected test level are tested.
Class |
Test levels ( kV ) |
Line to line |
Line to earth |
|||
Line to line |
Line to earth |
TEMA setup |
Example |
TEMA setup |
Example |
|
0 |
NA |
NA |
--- | --- | --- |
--- |
1 |
NA |
0.5 |
--- | --- | ||
2 |
NA |
1.0 |
--- | --- | ||
3 |
NA |
2.0 (3) |
--- | --- | ||
4 |
NA |
2.0 (3) |
--- | --- | ||
5 |
NA |
4.0 (3) |
--- | --- | ||
X |
||||||
| Equipment | Generator Version : MIG0603IN2 or IN3 or
TRA2000-IN6 + CDN-UTP Balanced Coupler |
|||||
(3) Normally tested with primary protection
5 pulses positive and 5 pulses negative are applied.
All lower levels including the selected test level are tested.