Power Frequency Magnetic Field Testing per IEC 61000-4-8

PFMF


Version : 21.03.03 , based on 61000-4-8:1993 /A2:2000

EMC-Partner Generator : TRA2000

 

1. General

Testing take place in climatic specification as follows:
Ambient temperature :               15°C to 35°C
Relative Humidity :                     25% to 75%
Atmospheric Pressure :              86kPa (860 mbar) to 106kPa (1060 mbar)
Other values may be specified in the test specification.

 


 

3. Test Levels

Level

Continous
field

Short
duration

Continous field

Short duration

   

1 to 3 sec

TEMA setup

Example

TEMA setup

Example

1

1 A/m

NA SETUP HTML SETUP HTML

2

3 A/m

NA

SETUP

HTML

SETUP

HTML

3

10 A/m

NA

SETUP

HTML

SETUP

HTML

4

30 A/m

300 A/m

SETUP

HTML

SETUP

HTML

5

100 A/m

1000 A/m

SETUP

HTML

SETUP

HTML

NA = not applicable