Pulsed Magnetic Field Testing per IEC 61000-4-9

PMF


Version : 21.03.03 , based on 61000-4-8:1993 /A2:2000

EMC-Partner Generator : TRA2000

 

1. General

Testing take place in climatic specification as follows:
Ambient temperature :               15°C to 35°C
Relative Humidity :                     25% to 75%
Atmospheric Pressure :              86kPa (860 mbar) to 106kPa (1060 mbar)
Other values may be specified in the test specification.

 


 

3. Test Levels

Level

Pulse magnetic
field strength

Pulse magnetic
field strength

   

TEMA setup

Example

1

NA

SETUP HTML

2

NA

SETUP

HTML

3

100 A/m

SETUP

HTML

4

300 A/m

SETUP

HTML

5

1000 A/m

SETUP

HTML

NA = not applicable