TC-ST

TC-ST

Test cabinet made of acrylic glass, With interlock safety switch.

Test cabinet for EUT with maximum dimensions 20 X 20 x 30cm. Mounted on top of the generator to cover high voltage outputs. Increases personnel safety. Can be used together with generators having output on top up to 30kV. Electro-mechanical locking mechanism to prevent opening when high voltage is enabled.

 Pulses

  • Combination Wave
  • Active Flammability Tests

 Documents

 Conducted Immunity

 Your Benefits

  • Usable with MIG generators with HV output on top.
  • Safety Interlock switch stops generator when cabinet open.
  • Red and gren warning lamps connected to safety circuit
  • Insulation withstand 1.2/50µs up to max. 36kV.
  • EUT dimensions 30x20x20cm

 Product Options

 


High speed communication lines
MIL-STD-461 conducted susceptibility to impulses and transients
Basic- and Product standard requirements & Solutions
Test cabinet made of acrylic glass, With interlock safety switch.
test cabinet, surge, 36kV
Red and gren warning lamps connected to safety circuit

Suitable for component testing Suitable for component testing

  • Combination Wave
  • Active Flammability Tests

TC-ST - Your Benefits


  • Usable with MIG generators with HV output on top.

  • Safety Interlock switch stops generator when cabinet open.

  • Red and gren warning lamps connected to safety circuit

  • Insulation withstand 1.2/50µs up to max. 36kV.

  • EUT dimensions 30x20x20cm
103532
IEC 61000-4-5
  • IEC 60384-14
  • IEC 60060-1
  • IEC 61008-1
  • IEC 61010-1
  • IEC 61051-1
  • IEC 61180
  • IEC 62305-4
  • IEC 61051-1
  • IEC 60947-1
  • UL 1414
  • Conducted Immunity,Telecom,MIL-STD-461 testing
    AVI (Volt.Spike),COMP (GDT),COMP (SPD),COMP (Varistor),IMU (DOW),IMU (Ringwave),IMU (Surge & CWG),INS (0.5 Joule,INS (40 Ohm),INS (500 Ohm),TEL (Light.Cur.),TEL (Light.Volt)
    IEC 60060-1
    IEC 61000-4-5
    IEC 60950-1
    IEC 61010-1
    IEC 60384-14
    UL 1414
    Protects personnel from high voltage or flying debris.
    Immediate visual indicator of test system status.
    Suitable for testing with high current and high voltage pulses
    Usable with MIG generators with HV output on top.
  • Safety Interlock switch stops generator when cabinet open.
  • Insulation withstand 1.2/50µs up to max. 36kV.
    EUT dimensions 30x20x20cm