Insulation Test Accessories

Insulation withstand: 1.2/50 up to 48kV
Max. Current: 3000A
Cable Length: 120cm
High Voltage Connector: 4mm insulated
Test connections to MIG generators with output on top

Connection box with 2 connection cables to EUT. Cable length 1.5m one red, one yellow. Standard accessories: alligator clips one yellow one red....

Lightning Pulse: 1.2/50
CS106 - Voltage Spike
Maximum voltage 1.2/50: 18kV
Maximum voltage d.c. of AMP connectors: 20kV
Maximum Impulse voltage 1.2/50 of the AMP connector: 24kV
Maximum current 8/20 of AMP connector: 500A
500 Ohm resistor cover box to generators MIG1803

Small cover boxe usable with generators MIG1803. The box includes the resistor, equipped with three AMP high voltage outputs: Common, Rgenerator and 500 Ohm....

Lightning Pulse: 1.2/50
Surge up to 12kV
Surge
Surge
Surge
Maximum voltage 1.2/50: 24kV
Maximum voltage d.c. of AMP connectors: 20kV
Maximum Impulse voltage 1.2/50 of the AM Connector: 24kV
Maximum current 8/20 of AMP connector: 500A
500 Ohm - Small cover box usable with generator MIG2403 up to 24kV

Small cover box usable with generators MIG2403. The box includes the resistor, equipped with three AMP outputs: Common, Rgenerator and 500 Ohm....

Lightning Pulse: 1.2/50
Impulse voltages adjusted for sea level
Four voltage ranges
Fixed impedance for each impulse level
Fixed energy for each impulse level
Protection relay impulse network for sea level tests

Protection relay impulse network Impulse voltages for sea level testing. Together with MIG1203 according to IEC 60255-5, 0.5 Joule,...

Lightning Pulse: 1.2/50
Specific energy (0.5J) pulses
Test voltages up to 4kV
Matching network for MIG1803

Electricity meter impulse network In accordance with IEC 62052-11 section 5.6. For use with MIG1803. 0.5 Joule, 500 Ohm at voltages...

Surge up to 12kV
Lightning Pulse: 1.2/50
Specific energy (0.5J) pulses
Impulse amplitudes 6kV to 12kV
MAtching network to MIG1803

Electricity meter impulse network In accordance with IEC 62052-11 section 5.6. For use with MIG1803. 0.5 Joule, 500 Ohm at voltages...

Lightning Pulse: 1.2/50
Surge up to 12kV
500 ohm external resistor matrix
Appropriate high voltage connectors
Matching network for use with MIG1203

Small cover box usable with generators MIG1203 or MIG1203CWG. The box includes a 500 Ohm resistor and is equipped with three AMP outputs: Common, Rgenerator and 500 Ohm...

Lightning Pulse: 1.2/50
Easy fitting onto standard generator
Four voltage levels
Fixed impedance at all impulse levels
Fixed energy at all impulse levels
Protection relay impulse newtork

Protection relay impulse network For MIG1803 according to IEC 60255-5, 0.5 Joule, 500 Ohm at voltages 900V, 1750V, 3000V, 7300V....

Lightning Pulse: 1.2/50
Easy fitting onto standard generator
Four impulse levels
Fixed impedance for each impulse level
Fixed energy for each impulse level
Protection relay impulse newtork

Protection relay impulse network For MIG1803 according to IEC 60255-5, 0.5 Joule, 500 Ohm at voltages 500V, 1000V, 2500V, 5000V....

Lightning Pulse: 1.2/50
Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.
More information Ok Decline