Insulation Test Generator

The 1.2/50µs Lightning impulse forms the basis for a variety of insulation test applications. From simple insulation tests of material to voltage breakdown of transformers. Solutions are available for these and also product safety testing.

  • Reliable solid state technology
  • Reproducible impulses
  • Integrated personnel safety features
  • Automatic PASS /FAIL detection
according to IEC 60060-1 and IEC 61180-2;
Integrated peak measurement for voltage and current
Safety in accordance with VDE 0104 (safety circuit, connector for warning lamp)
1.2/50

Insulation tester according to IEC 60060-1 and IEC 61180-2; 1.2/50 ...

Surge
Electronic polarity change
High degree of automation without software
Reliable solid state impulse switch
Insulation test system 1.2/50 up to 12kV

Insulation tester according to IEC 60060-1 and IEC 61180-2; 1.2/50 ...

Lightning Pulse: 1.2/50
according to IEC 60060-1
Insulation tester 1.2/50s, up to 12kV, 40 Ohm plus CWG 1.2/50s 6kV, 8/20s 300A up to 3kA

Insulation tester MIG1203CWG according to IEC 60060-1: 1.2/50 up to 12kV, 40 Ohm plus CWG 1.2/50 6kV Surge coupling onto power lines use automatic external CDN....

Combination Wave
Solid state impulse switch and solid state polarity change (no mechanical switch, no spark gaps or tubes) - advantages: low jitter, no high frequency switching noise.
Microprocessor menu controlled, printer port and RS232 remote control
Safety in accordance with VDE 0104 (safety circuit, connector for warning lamp)
Integrated peak measurement for voltage and current. Peak display and monitor output for v,i
Impulse generator fits through standard door width 80 cm
Insulation tester 1.2/50 with two source impedances: 48 Ohm and 500 Ohm. Up

Insulation tester; 1.2/50 48 output: v = 1.2/50 500 output: v = 1.2/50...

Combination Wave
Parameter ramp feature
High degree of automation without software
Electronic polarity change
Insulation tester 1.2/50 up to 24kV.

Insulation tester according to IEC 60060-1; 1.2/50 Outputs on top. Requires TC-MIG24 PN103532; or COVER BOX for customized connection between MIG2403 and EUT...

Lightning Pulse: 1.2/50
Solid state impulse switch and solid state polarity change (no mechanical switch, no spark gaps or tubes) - advantages: low jitters, no high frequency switching noise
Microprocessor menu controlled, printer port and RS232 remote control
Safety in accordance with VDE 0104 (safety circuit, connector for warning lamp)
Integrated peak measurement for voltage and current. Peak display and monitor output for v,i
Impulse voltage tester 1.2/50 voltage range 2kV up to 36kV.

Insulation tester according to IEC 60060-1; 1.2/50 V/I=12 Ohm and serial resistor 500 Ohm; V/I=2 Ohm and serial resistors 500 Ohm. Requires TC-MIG24 or CN-MIG48....

Combination Wave
Impulse voltage range from 2kV up to 72kV
Modular system extendable up to 144kV
Separate control unit
Solid state technology
Insulation tester up to 72kV

Insulation tester 1.2/50æs with impedances: 24 Ohm direct output: V = 1.2/50æs up to 72kV, I = 3000A, 500 Ohm with series resistor: V = 1.2/50æs up to 72kV, I = 144A...

Lightning Pulse: 1.2/50
Impulse voltage range from 2kV up to 72kV
Modular system extendable up to 144kV
Separate control unit
Soilid state technology
Insulation tester up to 120kV

Insulation tester 1.2/50æs with two outputs: 40 and Rs=500 Ohm. 40 output: v = 1.2/50æs up to 120kV, imax 3000A, WF approx. 8/20æs. 500 output: v = 1.2/50æs up to 120kV, imax 240A, WF not defined....

Lightning Pulse: 1.2/50
Lightning surge 1.2/50us, up to 18kV
Programmable Pass/Fail using internal impulse measurement
Programmable test routines from generator front panel
Electronic polarity change
Impulse voltage tester 1.2/50us voltage range 1kV up to 18kV.

Insulation tester according to IEC 60060-1 and IEC 61180-2; 1.2/50 ...

Integrated peak measurement for voltage and current. Peak display and monitor output for Voltage and Current.
Windows software for PC control available
Safety in accordance with VDE 0104 (safety circuit, connector for warning lamp)
Microprocessor menu controlled, printer port and RS232 remote control
Surge Generator according to IECF 61180-2. CWG 24kV, 12kA.

Surge Generator according to IECF 61180-2. CWG 24kV, 12kA. Designed for component tests. Requires TC-MIG24. ...

can also be used for inductive loads
contains a high energy with up to 960A in short circuit
Up to 6kV a hybrid generator is included with a current up to 3 kA Waveform (8/20)
Insulation Tester 1.2/50 up to 48 kV and 8/20 up to 3kA

Insulation tester according to IEC 60060-1; 1.2/50 control and high voltage part in one rack. Requires CN-MIG4803. ...

Lightning Pulse: 1.2/50
Current Pulse: 8/20
Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.