Test Accessories

Multicolour LED coupling path indication
Ready for EV and railway testing
ANSI coupling for Surge & Ring wave
Included cables and/or connectors
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 200A per phase

Three phase 200A automatic CDN for IMU. 6kV Burst, 6kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Multicolour LED coupling path indication
Up to 1500Vdc EUT voltage
Ready for EV and railway testing
Included cables and/or connectors
ANSI coupling for Surge & Ring wave
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 63A per phase

Three phase 63A automatic CDN for IMU. 6kV Burst, 6kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Multicolour LED coupling path indication
Up to 1500Vdc EUT voltage
Ready for EV and railway testing
ANSI coupling for Surge & Ring wave
Included cables and/or connectors
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 200A per phase

Three phase 200A automatic CDN for IMU. 7kV Burst, 8kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Multicolour LED coupling path indication
Up to 1500Vdc EUT voltage
Ready for EV and railway testing
Included cables and/or connectors
ANSI coupling for Surge & Ring wave
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 63A per phase

Three phase 63A automatic CDN for IMU. 7kV Burst, 8kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Surge CWG according to IEC 61000-4-5 Ed3
100kHz Ringwave according to IEC 61000-4-12
100kHz operating bandwidth
EUT current up to 3A
Maximum test level 6kV
Surge & Ringwave testing on up to 8 asymmetrical data lines

SURGE data line coupling-decoupling network IEC 61000-4-5 latest edition Unshielded unsymmetrical data lines...

Surge
Ringwave
Included cables and/or connectors
Up to 1000Vdc EUT voltage
Ready for EV and railway testing
ANSI coupling for Surge & Ring wave
EFT, Surge & Ring wave manual 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 32A per phase

Three phase 32A manual CDN for IMU. 6kV Burst, 6kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Superimpose EFT, Surge & Ringwave onto single and three phase power supply lines.
Three Phase CDN up to 6kV - Manually Operated for EFT, SURGE, RING WAVE Coupling

Three phase CDN with line voltages a.c. L to N/PE=280V and L to L=415V, line current 32A per phase. Manual coupling path selection for EFT, SURGE and RING up to 6kV....

EFT
Surge
Ringwave
according to IEC 61000-4-16.
Coupling network for common mode coupling dc, 50/60Hz and sinusoidal up to 150kHz 8 lines

Coupling network for common mode coupling dc, 50/60/16.7Hz and sinusoidal up to 150kHz according to IEC 61000-4-16. Testing on 8 lines....

Common mode continuous testing
Mains decoupling transformer single phase 230V/6A 50/60Hz. For coupling select CN16, or CN16DC

Mains decoupling transformer single phase 230V/6A 50/60Hz. For tests according to IEC 61000-4-16: DC, 50/60Hz and sinusoidal up to 150 kHz. Housing 19" 4 UHdc....

Common mode continuous testing
Voltage and Current tests possible with one unit
Exceeds maximum test levels in IEC 61000-4-19
Integrated Current source up to 25A. Maximum EUT voltage 500Vac
Controlled directly from IMU3000 or IMU4000 front panel
All modulation types possible.Connection for Reference meter during Current tests
IN PERFECT HARMONY - Signalling INTEREFERENCE in VOLTAGE & CURRENT Circuits

IMU SLAVE SMART I1V1 complies with IEC 61000-4-19 Ed1 Consists of: current generator CW 2kHz up to 150kHz Imax 4.4 A (EM) and current source 50/60Hz up to 25A. PS3 is required. (EM)...

Differential Mode
Differential Mode
Can be used with TRA3000 and IMU3000 / IMU4000
Test coil 1m x 2.6m for magnetic field test according -8 / -9 / -10

Test coil 1m x 2.6m for magnetic field test: 50/60Hz according to IEC 61000-4-8, SURGE according to IEC 61000-4-9,...

Magnetic Field
Magnetic Field
Magnetic Field
DC Interrupts up to a maximum 32A/480V.
AC Interrupts up to a maximum 32A/480V.
Coupling Path switching from Generator
EUT Connections via Banana Plug
3-Phase Interrupt Tester Type up to 32A/480V AC/DC

The PFS32 can generate interruptions on three phase power supply up to 480V/ 32A. For DIPS and supply configuration the PFS32 can be inserted in the SRC32 rack. Minimum configuration TRA or IMU with...

Dips & Interrupts DC
Dips
Power Source Extension for Three Phase testing of AC Interrupts up to 690V and 75A

The PFS75 can generate interruptions on three phase power supply up to 690V/ 75A. For DIPS and supply configuration the PFS75 can be inserted in the SRC75 rack. Minimum configuration...

AC Interrupts
DC Interrupts
18 Unit High rack with 3P transformer for 3 phase dips 40,50,70,80%.

18 Unit High rack with 3P transformer for 3 phase dips 40,50,70,80%. The rack has enough space for inserting PFS32 or PFS63. Minimum generator configuration: TRA2000 D; TRA3000 D-V;...

Dips
690Vac EUT voltage
75A per phase continuous current
Complies with IEC standard in rush current
Three phase source for dips testing

Extension to PFS75-690V. The SRC75-690V together wih the PFS75-690V can generate interruptions and DIPS on 3 phase power supply up to 690V/ 75A. Minimum generator configuration:...

Dips
Multicolour LED coupling path indication
Ready for EV and railway testing
ANSI coupling for Surge & Ring wave
Up to 1500Vdc EUT voltage
Included cables and/or connectors
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 125A per phase

Three phase 125A automatic CDN for IMU. 6kV Burst, 6kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Ready for railway testing
Up to 1500Vdc EUT voltage
Included cables and/or connectors
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 32A per phase

Three phase 32A automatic CDN for IMU. 6kV Burst, 6kV Surge, EUT max. 690Vac 500Vdc ...

Surge
EFT
Ringwave
Multicolour LED coupling path indication
Up to 1500Vdc EUT voltage
Ready for EV and railway testing
ANSI coupling for Surge & Ring wave
Included cables and/or connectors
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 125A per phase

Three phase 125A automatic CDN for IMU. 7kV Burst, 8kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Multicolour LED coupling path indication
Up to 1500Vdc EUT voltage
Ready for EV and railway testing
ANSI coupling for Surge & Ring wave
Included cables and/or connectors
EFT, Surge & Ring wave automatic 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 32A per phase

Three phase 32A automatic CDN for IMU. 7kV Burst, 7.6kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Surge CWG according to IEC 61000-4-5 Ed3
100kHz Ringwave according to IEC 61000-4-12
100kHz operating bandwidth
EUT current up to 3A
Maximum test level 6kV
Surge & Ringwave testing on up to 4 asymmetrical data lines

SURGE coupling-decoupling network for data lines according to IEC 61000-4-5. In accordance with ED3 Manual operated. Maximum 4 lines...

Surge
Ringwave
Fully compliant with a single CDN
Up to 1000Vdc EUT voltage
ANSI coupling for Surge & Ring wave
Included cables and/or connectors
EFT, Surge & Ring wave manual 3-phase CDN for power supply lines. EUT max 690Vac / 1500Vdc / 32A per phase

Three phase 32A manual CDN for IMU. 7kV Burst, 8kV Surge EUT max. 690Vac 500Vdc...

Surge
EFT
Ringwave
Line voltages L to N/PE=280V and L to L=480V
Automatic 3-Phase CDN up to 32A / 8kV for EFT, Surge and Ringwave (480V)

Three phase CDN with line voltages L to N/PE=280V and L to L=480V, line current 32A per phase. Manual coupling path selection for EFT, SURGE and RING....

Surge
EFT
Ringwave
Coupling network for common mode coupling dc up to 300V

Coupling network for common mode coupling dc up to 300V onto EUTpower line voltage Lto N/PE of 230V according to IEC 61000-4-16. The mains must be decoupled with a insulation transformer...

Common mode continuous testing
According IEC 61000-4-16:
Mains decoupling transformer single phase 230V/16A 50/60Hz. DC, 50/60Hz and sinusoidal up to 150 kHz

Mains decoupling transformer single phase 230V/16A 50/60Hz. For tests according to IEC 61000-4-16: DC, 50/60Hz and sinusoidal up to 150 kHz . Housing 19" 4 UH...

Common mode continuous testing
Easy extend to IEC 61000-4-16
Extension for common mode short duration tests according IEC 61000-4-16

Extends IMU generator with C module for short time tests IEC 61000-4-16 latest edition Upto 300V AC / DC tests with one PS3 power supply....

Common mode short testing
Can be used with TRA3000 and IMU3000 / IMU4000
Test coil 1m x 1m for magnetic field test according to IEC 61000-4-8 only for short duration 3s 1000A/m.

Test coil 1m x 1m for magnetic field test according to IEC 61000-4-8 only for short duration 3s 1000A/m. ...

Magnetic Field
Magnetic Field
Magnetic Field
Standalone Generator for DC Interupts (needs TRA or IMU Generator)
Interruption generator designed for d.c. interruption or dips on d.c.

Extends the TRA3000 D for d.c. interruption test D.C. Power fail simuator for Imax 100A d.c., Vmax 600V +/-10% Output floating DC+, DC- and GND, 4 UH, weight approx 50kg...

Dips & Interrupts DC
Power Source Extension for Three Phase testing of AC Interrupts up to 480V and 75A

The PFS75 can generate interruptions on three phase power supply up to 480V/ 75A. For DIPS and supply configuration the PFS75 can be inserted in the SRC75 rack. Minimum configuration TRA or IMU...

AC Interrupts
DC Interrupts
18 Unit High rack with 3P transformer for 3 phase dips 40,70,80%.

18 Unit High rack with 3P transformer for 3 phase dips 40,70,80%. Enough space for PFS32 or PFS63. Generator must be placed on top. Minimum generator configuration: TRA2000-D; TRA3000 D-V...

Dips
18 UH rack with 3P transformer for 3 phase dips 40,70,80% on mains 480V/75A

18 UH rack with 3P transformer for 3 phase dips 40,70,80%. on mains 480V/75A. Enough space for inserting PFS75 Minimum generator configuration: TRA2000 D; TRA3000 D-V;...

Dips
Works with all Generators of the IMU or TRA Series
Automated Variac control from Generator
Can also be used with AC magnetic field antenna
External 16A Variac for Dips and Variations

Extends IMU and TRA generators with 16A external variac For DIPS and variation, complies with IEC 61000-4-11 Requires a D circuit for Dips testing...

Dips
Variations
Two balun devices 10/50 Ohm in one unit
Designed for CDN verification in the differential test system
10/50 Ohm CDN calibration balun

2 x 10-50 Ohm balun in one box with MC connectors to connect to CDN and BNC to connect the VNA. VERI10-50 is designed to verify the CDN part of SLAVE SMART V1...

Differential Mode
Differential Mode
Integrated divider for EFT calibration
Designed for EFTcalibration up to 6kV.
50 Ohm EFT termination with HV BNC connectors

50 Ohm termination with high voltage BNC connectors and integrated divider for EFT calibration / verification. VERI50 EFT is designed for EFTcalibration up to 6kV....

EFT
Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.
More information Ok Decline