Telecom Testing Generators

Designed for ITU Basic & Enhanced Levels
Supports Power Induction Tests
Internal programm Memory
Application based solutions & Intuitive user interface
Power induction tester according to ITU- T K.44 and ITU-T K.45.

Power induction tester according to ITU- T K.44 and ITU-T K.45.  ...

Power Induction
Telecom tester according to ITU-T K.44: 10/700

Telecom tester according to ITU-T K.44: 10/700 waveforms, voltage up to12kV. Up to 12kV output on top, 6kV output on front panel. Current limiting reistors 2 x 25 Ohm....

Lightning Pulse: 1.2/50
Telecom 10-700
Generator according to IEC 61000-4-5
12kV/6kA 2 Ohm with automatic three phase coupling network 480V and 32A.
Combination Wave Generator according to IEC 61000-4-5 12kV/6kA 2 Ohm with automatic three phase coupling network 480V and 32A.

Combination Wave Generator according to IEC 61000-4-5 12kV/6kA 2 Ohm with automatic three phase coupling network 480V and 32A. With ITU-T K.44 10/700...

Combination Wave
Lightning Pulse: 1.2/50
Telecom 10-700
Current range 2 x 0.5kA minus 10% up to 2 x2.5kA+10%
Two generators each with 10/350us impulse
Combined generator outputs up to 5kA
For testing Type 1 SPDs
Test level user programmable
Impulse current generator 10/350

Impulse current generator 10/350 up to 2 x2.5kA+10%. Outputs can be switched in parallel 1x5kA +10% EPOS control with touch screen....

Current Pulse: 10/350
according to IEC 61000-4-5;12kV/6kA
2 Ohm with automatic single phase coupling network 480V and 32A.
Combination Wave Generator according to IEC 61000-4-5;12kV/6kA 2 Ohm with automatic single phase coupling network 480V and 32A

Combination Wave Generator according to IEC 61000-4-5;12kV/6kA 2 Ohm with automatic single phase coupling network 480V and 32A. With ITU-T K.44 10/700...

Combination Wave
Lightning Pulse: 1.2/50
Telecom 10-700
Current limiting resistor sets 2x 300, 2x 600, 2x 1000, 2x 1200 Ohm
Direct output for external limiting resistors
Control from TRA & IMU generators
Extension Network to perform Power Contact (PC) tests according to ITU-T K.44

Mains power contact network with current limiting resistors: 2x 300, 2x 600, 2x 1000, 2x 1200 Ohm Direct output for external limiting resistors (PCPI160)....