IMU SLAVE SMART I1V1

IMU SLAVE SMART I1V1

IN PERFECT HARMONY - Signalling INTEREFERENCE in VOLTAGE & CURRENT Circuits

Increasing use of MAINS SIGNALLING to control or gather data is a new challenge to electronic equipment. This differential mode disturbance of mains power lines is regulated by the standard IEC 61000-4-19 to perform tests in the frequency range 2kHz to 150kHz. Electricity meters are particularly vulnerable, signalling on the current circuit with potential to generate measurement error. An enhancement to the already popular IMU series of EMC testers, IMU SLAVE SMART V1I1 includes CW and MODULATED disturbance source, CDN for VOLTAGE circuits, REFERENCE meter connections and a 25A current source. Direct control from IMU series interfaces includes graphics and pre-programmed tests.

 Pulses

  • Differential Mode | up to  Current Tests
  • Differential Mode | up to  Voltage Tests

 Documents

 Conducted Immunity

 Your Benefits

  • Voltage and Current tests possible with one unit
  • Exceeds maximum test levels in IEC 61000-4-19
  • Integrated Current source up to 25A. Maximum EUT voltage 500Vac
  • Controlled directly from IMU3000 or IMU4000 front panel
  • All modulation types possible.Connection for Reference meter during Current tests

 Product Options

 


Basic- and Product standard requirements & Solutions
IN PERFECT HARMONY - Signalling INTEREFERENCE in VOLTAGE & CURRENT Circuits
IEC 61000-4-19, differential mode, tester, generator
Integrated Current source up to 25A. Maximum EUT voltage 500Vac

Automation at your disposal Automation at your disposal

  • Differential Mode | up to  Current Tests
  • Differential Mode | up to  Voltage Tests

IMU SLAVE SMART I1V1 - Your Benefits


  • Voltage and Current tests possible with one unit

  • Exceeds maximum test levels in IEC 61000-4-19

  • Integrated Current source up to 25A. Maximum EUT voltage 500Vac

  • Controlled directly from IMU3000 or IMU4000 front panel

  • All modulation types possible.Connection for Reference meter during Current tests
105685
IEC 61000-4-19
Conducted Immunity
IMU (Diff.Mode)
IEC 61000-4-19
True on site hardware and firmware updates
Quick learning and accommodation
Reliable solution ready for future requirements
Voltage and Current tests possible with one unit
  • Exceeds maximum test levels in IEC 61000-4-19
  • Controlled directly from IMU3000 or IMU4000 front panel
    All modulation types possible.Connection for Reference meter during Current tests

    Address

    EMC PARTNER AG
    Baselstrasse 160
    CH - 4242 Laufen
    Switzerland

    Follow us