X / Y CAPACITORS
X / Y capacitors are used for interference suppression on power supply inputs. The inputs may be subjected to impulse generated by lightning strikes on outside lines or switching in equipment. A 1.2/50us impulse is used for capacitor tests with and without AC power applied. In addition to the impulse insulation tests, active flammability tests are conducted to ensure the safety of equipment in event of a capacitor failing. The principle test requirements are defined in the standard IEC 61384-14. Edition 4 of the standard extends the scope for capacitors up to 50 µF.
APPLICATION STANDARDS
- IEC 61384-14
- UL 1414
- IEC 60060-1
- IEC 61384-1
TEST TYPES
- 1.2/50µs Voltage Impulse for Insulation Properties
- 1.2/50µs Voltage Impulse for Active Flammability
DOCUMENTS
-
-
pdf Brochure - Electrical Components Popular
SELECTED PRODUCTS
MORE OPTIONS & COMFORT
24 X / Y capacitor samples must be tested. This process can be automated by adding multiplexers to the generator high voltage outputs. Eight capacitor samples are fitted and tested sequentially under full control from the generator front panel. Combined with the TC-ST or TC-ST-F test cabi-nets, personnel safety is ensured.