Exchange equipment
Equipment mounted in the telephone exchange building can be subject to both external and internal EMC events. The test levels are necessarily high to ensure protection of the network. Many test requirements are embodied in the Network Equipment Building System (NEBS) specifications. EMC PARTNER provide telecom test equipment to meet the lightning voltage, lightning current, power contact and power induction requirements.
Application Standards
- ITU-T K44
- ITU-T K20
- ETSI/EN 300132-3-1
- ETSI/EN 300-132-2
- ETSI/EN 300386-1
Test Types
- 10/700µs Voltage Impulses
- 8/20µs Current Impulses
- AC Power Contact
- AC Power Induction
- Symmetrical Data Lines
Documents
-
-
-
pdf Infosheet - ESD3000 Popular
-
pdf Infosheet - ESD3000 (German) Popular
-
pdf Infosheet IMU F5 Edition Final Popular
-
pdf Infosheet - IMU Series (German) Popular
-
pdf Infosheet - New CDN Line Popular
-
pdf Infosheet - IMU Series Popular
-
pdf Brochure - ESD Test System Popular
-
pdf Brochure - Immunity Test System Popular
-
Product Page
8KV EFT / Burst, Surge, Ringwave and 10/700us impulse generator
Compact generator for EFT / Burst, Surge, 100 kHz Ringwave and 10/700 impulses up to 8KV. Integrated 16 A CDN. Extend with ESD, Dips/Interrupts and Common Mode.
Compact generator for EFT / Burst, Surge, 100 kHz Ringwave and 10/700 impulses up to 8KV. Integrated 16 A CDN. Extend with ESD, Dips/Interrupts and Common Mode.
Generator
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-12
24 kA impulse current generator with 4 outputs
Single and multiple pair lightning current test generator delivery an 8 / 20 us impulse from four independent outputs. 6 kA impulse current from each output or connected together 24 kA.
Single and multiple pair lightning current test generator delivery an 8 / 20 us impulse from four independent outputs. 6 kA impulse current from each output or connected together 24 kA.
Generator
IEC 61643-1
IEC 60060-1
ITU-T K.44
ITU-T K.21
ITU-T K.45
Power induction tester
The 1,500 V output meets all basic and enhanced test levels required by ITU- T K.20 and ITU-T K.21. Test duration is set manually on the generator front panel.
The 1,500 V output meets all basic and enhanced test levels required by ITU- T K.20 and ITU-T K.21. Test duration is set manually on the generator front panel.
Generator
IEC 61000-4-5
ITU-T K.20
ITU-T K.44
ITU-T K.21
More Options & Comfort
Test levels at the exchange or in repeater installations are higher than protected environments.EMC PARTNER equipment is available to cover both the basic and enhanced test requirements.